aquatherm green: PP-R / PP-RCT drinking water piping system
fusiolen PP-R and glass-fibre-reinforced PP-RCT pipe made in Germany (Attendorn and Ennest); SDR 6 / 7.4 / 9 / 11 classes, MF, MF RP and UV series, 20–315 mm. Stocked in Ankara since 1998, with custom manifold fabrication from the same pipe.
- Made in Germany
- 10-year insured warranty, EUR 20 million
- More than 50 years design life
- 450+ compatible fittings

Eight concrete advantages
Not marketing adjectives: measurable properties from the manufacturer's catalogue.
No corrosion
Polypropylene does not rust; no corrosion protection is needed and there is no scaling or corrosion-related leakage.
Hygienic, drinking-water approved
Free of plasticisers and heavy metals, odourless and tasteless. Hygienic suitability is documented by Hygiene-Institut Gelsenkirchen test reports and confirmed by continuous testing. Fusion joints mean no adhesives, solder or flux in the installation.
Homogeneous welded joint
Pipe and fitting are briefly heated and joined; the joint has double wall thickness and is stronger than the pipe itself. A 20 mm pipe is welded in 5 seconds and can be pressure tested or commissioned without a waiting period.
Low linear expansion (MF series)
Fibre-composite pipe expands at least 75% less than standard PP (α = 0.035 mm/(m·K) versus 0.15 for single-layer pipe); the coefficient is close to that of metal pipe, so support spacing is wider.
Opaque, low flow noise
The pipe is opaque, so there is no risk of algae growth inside; flow noise is lower than in metal pipe.
Low thermal conductivity
Thermal conductivity of 0.15 W/mK; less insulation is needed than for metal pipe (an advantage against condensation, for example in marine service lines).
Light weight
Lighter than steel and copper; PP pipe production uses up to 60% less energy and up to 85% less weight than metal (TEPPFA cradle-to-grave study). Marine page: steel 7,800 kg/m³, PP 980 kg/m³.
Environment
EPDs to ISO 14025 / EN 15804 (green/blue S/MF, UV, OT, ENERGY groups); the material is recyclable; aquatherm is a DGNB member. The company is certified to ISO 9001 (1996), 14001 (2012) and 50001 (2013).
Images and technical data: aquatherm GmbH (aquatherm green technical catalogue 09.2023, installation principles AS1059 and aquatherm.de). Values are as published by the manufacturer; the current catalogue governs project calculations.
aquatherm green variants and SDR classes
aquatherm classifies pipe by SDR (outside diameter / wall thickness), not PN. Lower SDR = thicker wall = higher pressure.

aquatherm green SDR 11 S
20–315 mm · fusiolen PP-R, single layer
Cold water installations (single-layer pipe suitable for media up to 45 °C; the drinking water pressure table gives only the 20 and 30 °C rows).
Colour: green, 4 blue stripes
aquatherm green SDR 7.4 S
20–63 mm · fusiolen PP-R, single layer
Cold and hot drinking water, small diameters.
Colour: green
aquatherm green SDR 6 S
20–110 mm · fusiolen PP-R, single layer
Thickest-walled single-layer series; highest pressure values in the drinking water table.
Colour: green

aquatherm green SDR 7.4 MF
20–32 mm · fusiolen PP-R, glass fibre middle layer
Hot and cold water; linear expansion at least 75% lower than standard PP pipe, and about 20% more flow at the same pressure thanks to the thinner wall.
Colour: green, 4 dark green stripes

aquatherm green SDR 7.4 MF UV
20–32 mm · fusiolen PP-R + polyethylene UV outer layer
Outdoor installation (lines exposed to sunlight).
Colour: green inner layer, black outer layer

aquatherm green SDR 9 MF RP
32–315 mm · fusiolen PP-RCT, glass fibre middle layer
Mains, risers and high temperature/pressure; the highest value of all series at 70 °C for 50 years (10.2 bar).
Colour: green, 4 dark green stripes

aquatherm green SDR 9 MF RP UV
32–315 mm · fusiolen PP-RCT + polyethylene UV outer layer
Outdoor mains.
Colour: green inner layer, black outer layer


There is no "SDR 7.4 MF RP" variant in the manufacturer's sources. For short sections, aquatherm's UV-resistant tape (art. no. 9700010871) can be used instead of UV-layered pipe; it is wrapped on a dry, clean surface with at least 50% overlap. Pipe is delivered in UV-protective packaging; outdoor storage only in undamaged original packaging and for at most 6 months from delivery. Take care against impact below 0 °C. The PN25 / PN20 / PN10 equivalence used in the Turkish market does not appear in the manufacturer's sources; select from the pressure-temperature table below. MF diameter range: 20–32 mm on the aquatherm.de product page, 20–250 mm in the catalogue article list; the current catalogue governs project selection.
Diameter, wall thickness, inside diameter, water content and weight
Full article list of the five series (catalogue pp. 61–63). UV variants have the same dimensions; only the weight differs.
green SDR 11 SSDR 11 / S 5 · 20–315 mm
| d × s (mm) | Inside dia. (mm) | Water (l/m) | Weight (kg/m) | DN | Joining |
|---|---|---|---|---|---|
| 20 × 1.9 | 16.2 | 0.206 | 0.108 | DN 15 | Socket fusion |
| 25 × 2.3 | 20.4 | 0.327 | 0.165 | DN 20 | Socket fusion |
| 32 × 2.9 | 26.2 | 0.539 | 0.261 | DN 25 | Socket fusion |
| 40 × 3.7 | 32.6 | 0.834 | 0.414 | DN 32 | Socket fusion |
| 50 × 4.6 | 40.8 | 1.307 | 0.641 | DN 40 | Socket fusion |
| 63 × 5.8 | 51.4 | 2.074 | 1.012 | DN 50 | Socket fusion |
| 75 × 6.8 | 61.4 | 2.959 | 1.411 | DN 65 | Socket fusion |
| 90 × 8.2 | 73.6 | 4.252 | 2.043 | DN 80 | Socket fusion |
| 110 × 10.0 | 90.0 | 6.359 | 3.026 | — | Socket fusion |
| 125 × 11.4 | 102.2 | 8.199 | 3.924 | DN 100 | Socket fusion |
| 160 × 14.6 | 130.8 | 13.430 | 6.415 | DN 125 | Butt welding |
| 200 × 18.2 | 163.6 | 21.010 | 9.992 | DN 150 | Butt welding |
| 250 × 22.7 | 204.6 | 32.861 | 15.548 | DN 200 | Butt welding |
| 315 × 28.6 | 257.8 | 52.172 | 24.664 | DN 250 | Butt welding |
Packaging: 4 m straight lengths (20 and 25 mm also in coils); 160–315 mm 5.8 m. Standards: DIN 8077 / 8078, DIN EN ISO 15874, ASTM F 2389, CSA B 137.11.
green SDR 7.4 SSDR 7.4 / S 3.2 · 20–63 mm
| d × s (mm) | Inside dia. (mm) | Water (l/m) | Weight (kg/m) | DN | Joining |
|---|---|---|---|---|---|
| 20 × 2.8 | 14.4 | 0.163 | 0.149 | DN 15 | Socket fusion |
| 25 × 3.5 | 18.0 | 0.254 | 0.232 | DN 20 | Socket fusion |
| 32 × 4.4 | 23.2 | 0.423 | 0.372 | DN 25 | Socket fusion |
| 40 × 5.5 | 29.0 | 0.660 | 0.578 | DN 32 | Socket fusion |
| 50 × 6.9 | 36.2 | 1.029 | 0.901 | DN 40 | Socket fusion |
| 63 × 8.6 | 45.8 | 1.647 | 1.416 | DN 50 | Socket fusion |
Packaging: 4 m straight lengths (20 mm also in coils). Standards: DIN 8077, DIN 8078, DIN EN ISO 15874, ASTM F 2389, CSA B 137.11.
green SDR 6 SSDR 6 / S 2.5 · 20–110 mm
| d × s (mm) | Inside dia. (mm) | Water (l/m) | Weight (kg/m) | DN | Joining |
|---|---|---|---|---|---|
| 20 × 3.4 | 13.2 | 0.137 | 0.174 | DN 12 | Socket fusion |
| 25 × 4.2 | 16.6 | 0.216 | 0.268 | DN 15 | Socket fusion |
| 32 × 5.4 | 21.2 | 0.353 | 0.437 | DN 20 | Socket fusion |
| 40 × 6.7 | 26.6 | 0.555 | 0.675 | DN 25 | Socket fusion |
| 50 × 8.3 | 33.4 | 0.876 | 1.047 | DN 32 | Socket fusion |
| 63 × 10.5 | 42.0 | 1.385 | 1.662 | DN 40 | Socket fusion |
| 75 × 12.5 | 50.0 | 1.963 | 2.351 | DN 50 | Socket fusion |
| 90 × 15.0 | 60.0 | 2.826 | 3.379 | DN 60 | Socket fusion |
| 110 × 18.3 | 73.4 | 4.229 | 5.040 | DN 65 | Socket fusion |
Packaging: 4 m straight lengths (20 and 25 mm also in coils). Standards: DIN 8077, DIN 8078, DIN EN ISO 15874, ASTM F 2389, CSA B 137.11.
green SDR 7.4 MFSDR 7.4 / S 3.2 · 20–250 mm
| d × s (mm) | Inside dia. (mm) | Water (l/m) | Weight (kg/m) | UV weight (kg/m) | DN | Joining |
|---|---|---|---|---|---|---|
| 20 × 2.8 | 14.4 | 0.163 | 0.157 | 0.210 | DN 15 | Socket fusion |
| 25 × 3.5 | 18.0 | 0.254 | 0.244 | 0.314 | DN 20 | Socket fusion |
| 32 × 4.4 | 23.0 | 0.423 | 0.391 | 0.485 | DN 25 | Socket fusion |
| 40 × 5.5 | 28.8 | 0.660 | 0.608 | 0.728 | DN 32 | Socket fusion |
| 50 × 6.9 | 36.2 | 1.029 | 0.948 | 1.101 | DN 40 | Socket fusion |
| 63 × 8.6 | 45.6 | 1.647 | 1.490 | 1.686 | DN 50 | Socket fusion |
| 75 × 10.3 | 54.4 | 2.323 | 2.120 | 2.347 | — | Socket fusion |
| 90 × 12.3 | 65.4 | 3.358 | 3.037 | 3.378 | DN 65 | Socket fusion |
| 110 × 15.1 | 79.8 | 4.999 | 4.546 | 5.054 | DN 80 | Socket fusion |
| 125 × 17.1 | 90.8 | 6.472 | 5.850 | 6.494 | — | Socket fusion |
| 160 × 21.9 | 116.2 | 10.599 | 9.559 | 9.859 | DN 125 | Butt welding |
| 200 × 27.4 | 145.2 | 16.558 | 14.944 | 15.273 | DN 150 | Butt welding |
| 250 × 34.2 | 181.6 | 25.901 | 23.312 | 23.630 | DN 175 | Butt welding |
Packaging: 4 m straight lengths; 160–250 mm 5.8 m. Standards: SKZ HR 3.28, ASTM F 2389, CSA B 137.11, ISO 21003, SKZ A314/616. SDR 9 MF RP UV is listed at 32–200 mm in the article list; the aquatherm.de product page gives 32–315 mm.
green SDR 9 MF RPSDR 9 / S 4 · 32–315 mm
| d × s (mm) | Inside dia. (mm) | Water (l/m) | Weight (kg/m) | UV weight (kg/m) | DN | Joining |
|---|---|---|---|---|---|---|
| 32 × 3.6 | 24.8 | 0.483 | 0.328 | 0.422 | DN 25 | Socket fusion |
| 40 × 4.5 | 31.0 | 0.754 | 0.511 | 0.630 | DN 32 | Socket fusion |
| 50 × 5.6 | 38.8 | 1.182 | 0.791 | 0.944 | DN 40 | Socket fusion |
| 63 × 7.1 | 48.8 | 1.869 | 1.261 | 1.457 | DN 50 | Socket fusion |
| 75 × 8.4 | 58.2 | 2.659 | 1.771 | 1.998 | — | Socket fusion |
| 90 × 10.1 | 69.8 | 3.825 | 2.553 | 2.894 | DN 65 | Socket fusion |
| 110 × 12.3 | 85.4 | 5.725 | 3.789 | 4.397 | DN 80 | Socket fusion |
| 125 × 14.0 | 97.0 | 7.386 | 4.886 | 5.530 | DN 100 | Socket fusion |
| 160 × 17.9 | 124.2 | 12.109 | 7.987 | 8.287 | DN 125 | Butt welding |
| 200 × 22.4 | 155.2 | 18.908 | 12.488 | 12.818 | DN 150 | Butt welding |
| 250 × 27.9 | 194.2 | 29.605 | 19.422 | — | DN 200 | Butt welding |
| 315 × 35.2 | 244.6 | 46.966 | 30.876 | — | DN 250 | Butt welding |
Packaging: 32–125 mm 4 m straight lengths; 160–315 mm 5.8 m straight lengths. Standards: SKZ HR 3.28, ASTM F 2389, ISO 21003, SKZ A632/A644. SDR 9 MF RP UV is listed at 32–200 mm in the article list; the aquatherm.de product page gives 32–315 mm.
How to read SDR
SDR = outside diameter ÷ wall thickness. For a 20 × 1.9 mm pipe, 20 / 1.9 ≈ 11. At the same diameter an SDR 7.4 pipe has a thicker wall; SDR 9 MF RP, thanks to PP-RCT and glass fibre, achieves a higher temperature-pressure rating and more flow with a thinner wall.
Standard lengths
4 m straight lengths up to 125 mm, 5.8 m from 160 mm. 20 and 25 mm S pipe can also be supplied in coils. Quantities in quotes are rounded to full lengths.
Download the catalogueImages and technical data: aquatherm GmbH (aquatherm green technical catalogue 09.2023, installation principles AS1059 and aquatherm.de). Values are as published by the manufacturer; the current catalogue governs project calculations.
Permissible working pressure (bar)
Project calculations are based on these tables, not on a PN label. In lines with segment (butt-welded) fittings the values are multiplied by 0.75.
Potable water5 series · 20–70 °C · 1–50 years
| Temperature | Years | SDR 11 S | SDR 7.4 S | SDR 6 S | SDR 7.4 MF | SDR 9 MF RP |
|---|---|---|---|---|---|---|
| 20 °C | 1 | 15.0 | 23.8 | 30.0 | 28.6 | 25.0 |
| 5 | 14.1 | 22.3 | 28.1 | 26.8 | 24.2 | |
| 10 | 13.7 | 21.7 | 27.3 | 26.1 | 23.9 | |
| 25 | 13.3 | 21.1 | 26.5 | 25.3 | 23.5 | |
| 50 | 12.9 | 20.4 | 25.7 | 24.5 | 23.1 | |
| 30 °C | 1 | 12.8 | 20.2 | 25.5 | 24.3 | 21.7 |
| 5 | 12.0 | 19.0 | 23.9 | 22.8 | 21.0 | |
| 10 | 11.6 | 18.3 | 23.1 | 22.0 | 20.6 | |
| 25 | 11.2 | 17.7 | 22.3 | 21.3 | 20.2 | |
| 50 | 10.9 | 17.3 | 21.8 | 20.7 | 19.9 | |
| 40 °C | 1 | — | 17.1 | 21.5 | 20.5 | 18.7 |
| 5 | — | 16.0 | 20.2 | 19.2 | 18.0 | |
| 10 | — | 15.6 | 19.6 | 18.7 | 17.7 | |
| 25 | — | 15.0 | 18.8 | 18.0 | 17.3 | |
| 50 | — | 14.5 | 18.3 | 17.5 | 17.1 | |
| 50 °C | 1 | — | 14.5 | 18.3 | 17.5 | 15.9 |
| 5 | — | 13.5 | 17.0 | 16.2 | 15.3 | |
| 10 | — | 13.1 | 16.5 | 15.7 | 15.1 | |
| 25 | — | 12.6 | 15.9 | 15.2 | 14.7 | |
| 50 | — | 12.2 | 15.4 | 14.7 | 14.5 | |
| 60 °C | 1 | — | 12.2 | 15.4 | 14.7 | 13.5 |
| 5 | — | 11.4 | 14.3 | 13.7 | 13.0 | |
| 10 | — | 11.0 | 13.8 | 13.2 | 12.7 | |
| 25 | — | 10.5 | 13.3 | 12.6 | 12.4 | |
| 50 | — | 10.1 | 12.7 | 12.1 | 12.2 | |
| 65 °C | 1 | — | 11.6 | 14.6 | 13.9 | 12.4 |
| 5 | — | 10.8 | 13.6 | 12.9 | 11.9 | |
| 10 | — | 10.4 | 13.1 | 12.5 | 11.7 | |
| 25 | — | 10.0 | 12.6 | 12.0 | 11.4 | |
| 50 | — | 8.8 | 11.1 | 10.6 | 11.2 | |
| 70 °C | 1 | — | 10.3 | 13.0 | 12.4 | 11.4 |
| 5 | — | 9.5 | 11.9 | 11.4 | 10.9 | |
| 10 | — | 9.3 | 11.7 | 11.1 | 10.7 | |
| 25 | — | 8.0 | 10.1 | 9.6 | 10.4 | |
| 30 | — | 7.0 | 8.8 | 9.3 | 10.3 | |
| 50 | — | 6.7 | 8.5 | 8.1 | 10.2 |
Medium: water to DIN 2000; high flow rates, disinfectants and increased oxygen content are covered by the safety factors. SDR 11 S is given only for 20–30 °C cold water. Segment fitting factor 0.75.
General applicationsSDR 7.4 MF and SDR 9 MF RP · 10–90 °C · 5–100 years
| Temperature | Years | SDR 7.4 MF | SDR 9 MF RP |
|---|---|---|---|
| 10 °C | 10 | 27.7 | 27.5 |
| 25 | 26.9 | 27.1 | |
| 50 | 26.1 | 26.7 | |
| 100 | 25.2 | 26.3 | |
| 15 °C | 10 | 26.9 | 25.7 |
| 25 | 26.1 | 25.2 | |
| 50 | 25.3 | 24.9 | |
| 100 | 24.5 | 24.5 | |
| 20 °C | 10 | 26.1 | 23.9 |
| 25 | 25.3 | 23.5 | |
| 50 | 24.5 | 23.1 | |
| 100 | 23.7 | 22.8 | |
| 30 °C | 10 | 22.0 | 20.6 |
| 25 | 21.3 | 20.2 | |
| 50 | 20.7 | 19.9 | |
| 100 | 20.0 | 19.7 | |
| 40 °C | 10 | 18.7 | 17.7 |
| 25 | 18.0 | 17.3 | |
| 50 | 17.5 | 17.1 | |
| 100 | 16.8 | 16.8 | |
| 50 °C | 10 | 15.7 | 15.1 |
| 25 | 15.2 | 14.7 | |
| 50 | 14.7 | 14.5 | |
| 100 | 14.1 | 14.3 | |
| 60 °C | 10 | 13.2 | 12.7 |
| 25 | 12.6 | 12.4 | |
| 50 | 12.1 | 12.2 | |
| 70 °C | 10 | 11.1 | 10.7 |
| 25 | 9.6 | 10.4 | |
| 50 | 8.1 | 10.2 | |
| 75 °C | 10 | 10.0 | 9.7 |
| 25 | 8.0 | 9.5 | |
| 50 | 6.7 | 9.3 | |
| 80 °C | 5 | 9.2 | 9.0 |
| 10 | 7.8 | 8.9 | |
| 25 | 6.2 | 8.6 | |
| 90 °C | 5 | 6.0 | 7.4 |
| 10 | 5.1 | 7.3 |
For media other than water and drinking water, material-medium compatibility is checked separately (chemical resistance table). Segment fitting factor 0.75.
Short-term peaks of 100 °C are not a problem; continuous 70–90 °C shortens pipe life (see the pressure table). Intermittent system disinfection: at most twice a year, 50 mg/l free chlorine for at most 12 hours, or 150 mg/l H₂O₂ for at most 24 hours; 30 °C must not be exceeded during treatment. Chlorine dioxide must never be used. Continuously chlorinated drinking water: up to 0.3 mg/l free chlorine, at most 70 °C. Images and technical data: aquatherm GmbH (aquatherm green technical catalogue 09.2023, installation principles AS1059 and aquatherm.de). Values are as published by the manufacturer; the current catalogue governs project calculations.
Material properties and linear expansion
Formula: ΔL = α × L × ΔT; α = 0.15 mm/(m·K) single layer, 0.035 mm/(m·K) fibre composite. Example: 0.035 mm/(m·K) × 25 m × 40 K = 35 mm.
| Property | fusiolen PP-R (S) | PP-R / PP-RCT fibre (MF, MF RP) |
|---|---|---|
| Melt flow index 190 °C / 5 kg | 0.5 g/10 min | 0.5 g/10 min |
| Melt flow index 230 °C / 2.16 kg | 0.3 g/10 min | 0.3 g/10 min |
| Modulus of elasticity | 800 N/mm² | 1200 N/mm² |
| Yield stress | 25 N/mm² | 30 N/mm² |
| Density | 0.9 g/cm³ | 1.0 g/cm³ |
| Tensile strength | 25 MPa | 35 MPa |
| Ignition temperature | 430–450 °C | 490–500 °C |
| Coefficient of thermal expansion | 1.5 × 10⁻⁴ K⁻¹ | 0.35 × 10⁻⁴ K⁻¹ |
| Thermal conductivity (measured on the pipe) | 0.15 W/mK | 0.15 W/mK |
| Pipe friction coefficient | 0.007 | 0.007 |
| Bending radius | 6 × d | — |
| Water absorption | < 0.02 % | < 0.02 % |
| Relative dielectric constant (1 MHz) | 2.3 | 2.3 |
| Breakdown voltage | 500 kV/cm | 500 kV/cm |
| Specific resistance | > 10¹⁷ Ω·cm | > 10¹⁷ Ω·cm |
| Surface resistance | 10¹⁴ Ω | 10¹⁴ Ω |
| Pipe length | ΔT 10 K | ΔT 20 K | ΔT 30 K | ΔT 40 K | ΔT 50 K | ΔT 60 K | ΔT 70 K | ΔT 80 K |
|---|---|---|---|---|---|---|---|---|
| 5 m | 8 | 15 | 23 | 30 | 38 | 45 | 53 | 60 |
| 10 m | 15 | 30 | 45 | 60 | 75 | 90 | 105 | 120 |
| 20 m | 30 | 60 | 90 | 120 | 150 | 180 | 210 | 240 |
| 30 m | 45 | 90 | 135 | 180 | 225 | 270 | 315 | 360 |
| 50 m | 75 | 150 | 225 | 300 | 375 | 450 | 525 | 600 |
| Pipe length | ΔT 10 K | ΔT 20 K | ΔT 30 K | ΔT 40 K | ΔT 50 K | ΔT 60 K | ΔT 70 K | ΔT 80 K |
|---|---|---|---|---|---|---|---|---|
| 10 m | 4 | 7 | 11 | 14 | 18 | 21 | 25 | 28 |
| 20 m | 7 | 14 | 21 | 28 | 35 | 42 | 49 | 56 |
| 50 m | 18 | 35 | 53 | 70 | 88 | 105 | 123 | 140 |
| 100 m | 35 | 70 | 105 | 140 | 175 | 210 | 245 | 280 |
Expansion is absorbed by a bending arm, an expansion loop or pre-stressing; on long straight runs compensation is recommended every 10 m (formulae in installation principles pp. 8–11).
Pressure loss and expansion calculators
Pressure loss by SDR series, diameter, flow rate and temperature; ΔL, bending arm and expansion loop size for PP-R and fibre-reinforced pipe. For preliminary sizing; the tools are in Turkish.
Images and technical data: aquatherm GmbH (aquatherm green technical catalogue 09.2023, installation principles AS1059 and aquatherm.de). Values are as published by the manufacturer; the current catalogue governs project calculations.
Support (clamp) spacing
Clamp spacing is selected by diameter and temperature difference (ΔT); fixed points (FP) and sliding points (SP) are distinguished.
| ΔT (K) | 20 mm | 25 mm | 32 mm |
|---|---|---|---|
| 0 | 120 | 140 | 160 |
| 20 | 90 | 105 | 120 |
| 30 | 90 | 100 | 120 |
| 40 | 85 | 95 | 110 |
| 50 | 85 | 95 | 110 |
| 60 | 80 | 90 | 105 |
| 70 | 70 | 80 | 95 |
Where the green PDF shows an implausible value (misprint), the identical table in the aquatherm blue installation principles PDF (07/2026, p. 7) was used.
| ΔT (K) | 20 mm | 25 mm | 32 mm |
|---|---|---|---|
| 0 | — | — | 155 |
| 20 | — | — | 115 |
| 30 | — | — | 115 |
| 40 | — | — | 105 |
| 50 | — | — | 100 |
| 60 | — | — | 100 |
| 70 | — | — | 90 |
Where the green PDF shows an implausible value (misprint), the identical table in the aquatherm blue installation principles PDF (07/2026, p. 7) was used.
| ΔT (K) | 20 mm | 25 mm | 32 mm |
|---|---|---|---|
| 0 | 60 | 75 | 90 |
Clamps and fixed points
Clamps are selected for the outside diameter of the plastic pipe and must not damage the pipe surface (aquatherm clamps art. no. 9600060516–9600060660). Fixed points divide the line into sections and are dimensioned to carry expansion forces and additional loads. Swinging hangers are not used as fixed points. In risers, no expansion piece is needed if there is a fixed point immediately before and after each branch.
Sliding points and vertical lines
Sliding clamps must allow axial movement; nearby fittings or valves must not obstruct it. MF and S pipe: sliding point 1 spacer ring, fixed point 0 spacer rings. In vertical lines clamp spacing may be increased by about 20%.
Unit: cm (the PDF gives no unit; values of 60–325 are interpreted as cm). Values for 40 mm and above are not given in the installation principles PDF; consult the manufacturer for support spacing in larger diameters. Images and technical data: aquatherm GmbH (aquatherm green technical catalogue 09.2023, installation principles AS1059 and aquatherm.de). Values are as published by the manufacturer; the current catalogue governs project calculations.
Where is it used?
Flow velocity ≤ 0.5 m/s in hot water circulation; copper in the water ≤ 0.1 mg/l in mixed installations with copper.
Drinking water installations
Cold and hot water, hot water circulation, buried lines, mixed installations in refurbishment; suitable for chemical and thermal disinfection. Residential, hotel, healthcare, public and industrial buildings.
Shipbuilding and offshore
Drinking water, hot and cold water distribution, ballast water (together with blue), technical water systems; light weight and corrosion resistance in salt-laden environments. More than 450 pipes and fittings in 20–355 mm; prefabricated manifolds.
Swimming pool technology
The catalogue lists green under pool technology; the aquatherm.de pool page highlights aquatherm blue.
Agriculture / irrigation
Agricultural irrigation systems.
Industrial media
High chemical resistance; material-medium compatibility must always be checked separately (with temperature, pressure and external load) — chemical resistance table and aquatherm technical advice.
Hot water circulation rules
- The highest hot water temperature in the system should not exceed 60 °C; some regulations set a 50 °C limit at the tap.
- Thermal disinfection (for example in healthcare) may be carried out briefly at 70 °C and above; the limits of the pressure table must not be exceeded.
- Flow velocity should not exceed 0.5 m/s anywhere in the system (up to 1 m/s in special cases).
- A hydraulic balancing valve is mandatory in every circulation loop.
- When connecting to an existing copper system, measure the copper content of the water; 0.1 mg/l (ppm) must not be exceeded. Damage caused by copper corrosion is excluded from the warranty.
- Avoid water hammer and excessive pressure fluctuation; select the pump head to suit the installation.
These rules apply only to drinking water hot water circulation systems, not to cold water, heating or cooling systems.
Mixed installations and disinfection
Even if aquatherm pipe is resistant to a medium, other components in the installation (valves, pumps, check valves, strainers) may not be; the compatibility of all components with the medium must be verified before installation. PP needs no protection, but metal components may be prone to corrosion.
Thermal disinfection to DVGW W 551 is possible: at least 3 minutes at 70 °C at every point of the system. Continuously chlorinated drinking water: up to 0.3 mg/l free chlorine, at most 70 °C. Chlorine dioxide is not permitted.
Which standards is it produced to?
Pipe standards
| Series | Standard / test basis |
|---|---|
| S (single layer) | DIN 8077 / 8078, DIN EN ISO 15874, ASTM F 2389, CSA B 137.11 |
| MF (PP-R fibre) | SKZ HR 3.28, ASTM F 2389, CSA B 137.11, ISO 21003, SKZ A314/616 |
| MF RP (PP-RCT fibre) | SKZ HR 3.28, ASTM F 2389, ISO 21003, SKZ A632/A644 |
| Fittings | DIN 16962, DIN EN ISO 15874 |
Hygiene: Hygiene-Institut Gelsenkirchen test reports; compliance with DIN 1988 T2 and the KTW recommendations.
Fire classification: DIN 4102 B2 (normally flammable), DIN EN 13501 class E; no dioxin release in case of fire. Approved firestop systems (Rockwool Conlit 150 U, Flamro AWM II, Hilti) are required at wall and ceiling penetrations.
National approvals
- DVGW, SKZ, HIG (Germany)
- ÖVGW (Austria)
- WRAS (United Kingdom)
- AENOR (Spain)
- SAI-Global (Australia)
- CSTB, CARSO (France)
- SII (Israel)
- TIN (Poland)
- SITAC, KIWA, SWEDCERT (Sweden)
- IIP (Italy)
- BNQ (Canada)
- BRANZ (New Zealand)
- CERTIF (Portugal)
- EMI (Hungary)
German certificates (DVGW / SKZ)
- DVGW certificate: green pipe SDR 6 S (DW-8501AS2120 / DW-8501AU2224)2029-06 · 1.6 MB
- SKZ A 644 Rev. 2: green pipe MF RP (SDR 9)2028-10 · 1.7 MB
- SKZ A 314: green pipe SDR 7.4 MF2031-05 · 11.3 MB
- SKZ A 175: green pipe SDR x S2031-05 · 11.2 MB
The current approval document on aquatherm.de governs the certificate-product assignment; certificates are valid only in the country of issue. The marine page notes that DNV, BV, LR, RINA, ABS, CCS and KR class societies require approval; which class holds which document for green is not stated in the source texts. Contact us for Turkish-specific TSE / İSKİ documents.
Joining methods and welding parameters
All methods are fusion based: pipe and fitting become one piece under heat, without gaskets or adhesives. Welding standard: DVS 2207 Part 11 (general rules for heated-tool socket welding).
| Method | Diameter range / note |
|---|---|
| Socket fusion (hand tool) | 20–63 mm |
| Socket fusion (welding machine) | 50–125 mm |
| Electric welding jig | 63–125 mm |
| Butt welding | 160–630 mm (largest green pipe: 315 mm) |
| Electrofusion socket | 20–250 mm; hard-to-reach locations. Not applied directly to injection-moulded fittings — a pipe section is welded in between. |
| Weld-in saddle | Branches added later; listed on the aquatherm.de green processing page, diameter range not given for green |
| Push-fit fittings | Up to 40% faster than electrofusion, fewer tools; the catalogue lists 90–450 mm SDR 11 / 17.6 push-fit parts |

| Outside dia. (mm) | Heating DVS (s) | Heating AQE (s) | Joining (s) | Cooling (min) | Welding depth (mm) |
|---|---|---|---|---|---|
| 20 | 5 | 8 | 4 | 2 | 14.5 |
| 25 | 7 | 11 | 4 | 2 | 16.0 |
| 32 | 8 | 12 | 6 | 4 | 18.0 |
| 40 | 12 | 18 | 6 | 4 | 20.5 |
| 50 | 18 | 27 | 6 | 4 | 23.5 |
| 63 | 24 | 36 | 8 | 6 | 27.5 |
| 75 | 30 | 45 | 8 | 8 | 30.0 |
| 90 | 40 | 60 | 8 | 8 | 33.0 |
| 110 | 50 | 75 | 10 | 8 | 37.0 |
| 125 | 60 | 90 | 10 | 8 | 40.0 |
160–630 mm are joined by butt welding. AQE times are aquatherm's recommendation for ambient temperatures below +5 °C.
Pressure test
- Medium: water; test pressure 10 bar. A 10 K temperature difference causes a 0.5–1 bar pressure deviation, so keep the test medium at a constant temperature.
- Preliminary test: 3 × 5 minutes at 18 bar (to stretch and relax the pipe); pressure is released between cycles. (10 bar for SDR 17.6.)
- Main test: 15 minutes at 10 bar immediately after the preliminary test; drop at most 0.5 bar.
- Final test: 60 minutes (75 min in total); drop at most 0.5 bar. The gauge must read 0.1 bar and is fitted at the lowest point where possible.
- Report: signed by client and contractor with place and date (form on p. 20 of the installation principles). A documented pressure test is a warranty condition.
Insulation
Minimum insulation to EnEV/GEG on hot water lines; anti-condensation insulation on cold lines. Installation principles pp. 14–15 give a humidity-temperature condensation table for 75/110/160 mm.
Contact us for installation training and welding machine hire.
Images and technical data: aquatherm GmbH (aquatherm green technical catalogue 09.2023, installation principles AS1059 and aquatherm.de). Values are as published by the manufacturer; the current catalogue governs project calculations.
10-year insured manufacturer's warranty
10 years on all pipes and fittings (instead of the 2 years required by German law), backed by an insurance policy. It starts on the delivery date and takes effect with a documented pressure test to the aquatherm specification.
- Years 1–5: EUR 20 million per claim, EUR 40 million per year
- Years 6–10: EUR 8.5 million per claim, EUR 17 million per year
- Scope: property damage, financial loss and personal injury; design projects (PI) sub-limit EUR 2 million per claim, EUR 6 million per year
- Non-compliance with the operating parameters in aquatherm technical documents
- Non-compliance with installation rules / the aquatherm clamp system, or with national installation codes
- Faulty welding technique, dirty or unsuitable tools, untrained installers
- Improper connection to other systems (threads, flanges, mechanical joints); all sealing elements
- Systems without an aquatherm pressure test; improper handling after delivery
- Damage from copper corrosion in circulation lines; damage from air, cavitation and pressure surges
The insured warranty is the manufacturer's; Kaskyapı separately guarantees its own fabrication and pressure test for the manifolds it produces. Source: aquatherm GmbH (catalogue pp. 55–56).
Green, blue or red?
| aquatherm green | aquatherm blue | aquatherm red | |
|---|---|---|---|
| Main use | Drinking water, ships and yachts, pools, agriculture, industrial water | Heating and cooling, fan coil, chilled water | Sprinkler / fire protection |
| Distinguishing feature | Drinking water approvals, hygiene | Oxygen-barrier (OT) variant | Fire approvals (by country) |
| Colour | Green | Blue | Red |
| Manifold fabrication | Yes — meter and distribution manifolds | Yes — heating and cooling manifolds | Project basis |
Related pages
Blue pipe
PP-R / PP-RCT system for heating, cooling and fan coil lines.
Go to page aquatherm redRed pipe
Corrosion-free PP-R system for sprinkler installations.
Go to page Kaskyapı workshopPPRC manifold fabrication
Custom manifolds from green pipe with weld-in saddles, delivered pressure tested.
Go to pageaquatherm green — frequently asked questions
Where is aquatherm green used?
In water lines that require permanent leak-tightness, corrosion resistance and hygiene: drinking water, ships and yachts, swimming pools and leisure facilities, agriculture and chemical media.
Which variants are available?
Single-layer S (SDR 6, 7.4, 11), fibre-reinforced MF (SDR 7.4), raised-pressure MF RP (SDR 9) and, for outdoor use, the UV-layered MF UV / MF RP UV. Selection depends on pressure, temperature and ambient conditions.
Is there a PN rating?
aquatherm documents use SDR classes and temperature/lifetime-based working pressure tables rather than PN. The PN25 / PN20 / PN10 equivalence used in the Turkish market does not appear in the manufacturer's sources; pressure selection must be made from the table.
What should be observed during installation?
Joints are made by fusion without adhesives or sealants; in mixed installations the media compatibility of all components is checked in advance; in hot water circulation, temperature, flow velocity and hydraulic balancing must comply with the standards.
What pressure does aquatherm green withstand?
For drinking water at 20 °C and 50 years of operation: SDR 11 S 12.9 bar, SDR 7.4 S 20.4 bar, SDR 6 S 25.7 bar, SDR 7.4 MF 24.5 bar, SDR 9 MF RP 23.1 bar. At 70 °C for 50 years SDR 9 MF RP gives the highest value at 10.2 bar. The full table is on this page.
What water temperature is aquatherm pipe suitable for?
The highest hot water temperature in the system should not exceed 60 °C; some regulations set 50 °C at the tap. Thermal disinfection to DVGW W 551 is possible: at least 3 minutes at 70 °C at every point of the system. Short-term peaks of 100 °C are not a problem; continuous 70–90 °C shortens pipe life (see the pressure table).
What are the welding temperature and times?
Socket fusion is carried out to DVS 2207-11; for a 20 mm pipe: heating 5 s, joining 4 s, cooling 2 min, welding depth 14.5 mm. The parameter table up to 125 mm is on this page; 160 mm and above are butt welded.
What are the warranty conditions?
10 years on all pipes and fittings, backed by an insurance policy; it starts on the delivery date and takes effect with a documented pressure test to the aquatherm specification. Years 1–5: EUR 20 million per claim, EUR 40 million per year; years 6–10: EUR 8.5 million per claim, EUR 17 million per year. Cover: property damage, financial loss and personal injury.
What is the service life of aquatherm green?
Pressure-temperature values are extrapolated for a 50-year service life; the manufacturer's catalogue states "more than 50 years". The general applications table also gives 100-year rows for 10–50 °C.
How do I get the 2026 price list?
List prices are set by the manufacturer in foreign currency and project or quantity discounts apply, so the PDF price list and a project quote go together. Use the quote form on this page or the price list page (Turkish).
Catalogue, tables and certificates
aquatherm GmbH publications in their original English; Turkish versions prepared by Kaskyapı are secondary. The manufacturer's original is the binding document.
- aquatherm green technical catalogue (09.2023, 99 pages)Variants, pressure table, material, disinfection, certificates, warranty, article listPDF · 13.5 MB
- Permissible working pressure – potable water5 series × 20–70 °C × 1–50 yearsPDF · 0.04 MB
- Permissible working pressure – general applicationsSDR 7.4 MF and SDR 9 MF RP, 10–90 °C, 5–100 yearsPDF · 0.04 MB
- aquatherm green installation principles (AS1059, 09.2023, 22 pages)Fixing, linear expansion, expansion loops, support spacing, insulation, pressure test and report formPDF · 4.7 MB
- Table of loss coefficientsZeta values of fittings; common to all aquatherm systemsPDF · 0.22 MB
- aquatherm price list 2026By form (Turkish)
Images and technical data: aquatherm GmbH (aquatherm green technical catalogue 09.2023, installation principles AS1059 and aquatherm.de). Values are as published by the manufacturer; the current catalogue governs project calculations. Diameter range: 20–315 mm (aquatherm.de).
Get a 2026 quote
Enter product, diameter and quantity; we reply with price and delivery date as soon as possible. You can attach a drawing for manifolds.
Is your take-off for aquatherm green ready?
Send diameter and quantity on WhatsApp; we reply quickly with stock status and 2026 prices.